Triple fault when jumping to p-mode
Re: Triple fault when jumping to p-mode
so, i changed code base from 1000h:0 to 0:8000h and executed the code under Bochs in debug mode. it works fine. '+' character is displayed on the screen and then jmp $ stuns the system. but in Bochs (not debug mode) the same problem is present - infinite reboot. maybe it's smth with Bochs??? research on the subj is in progress....
Re: Triple fault when jumping to p-mode
DAMN!!! I GOT IT!!!
interrupts should not be enabled because IDT is not set up correctly, yet!
such a stupid mistake. sorry that I have bothered all of you
Code: Select all
pmode:
mov ax, 10h
mov gs, ax
mov fs, ax
mov byte [gs:0B8000h], '+'
sti ;<<<<<< that is the problem!!!!!
jmp $
such a stupid mistake. sorry that I have bothered all of you