; Fdd info                                       11/12/03 ;
;---------------------------------------------------------;
; DOS EXTREME OS V0.01                                    ;
; by Craig Bamford.                                       ;
;                                                         ;
; Pmode floppy disk driver.                               ;                          
;=========================================================;

DorReg            =   0x3f2                              ; digital output register (write only).
MsReg             =   0x3f4                              ; main status register (read only).
DtReg             =   0x3f5                              ; data register (read/write).
CcrReg            =   0x3f7                              ; configuration control register.

Sr0_AbTerm        =   6                                  ; test if aborted
Sr0Seek           =   5                                  ; test if seek ok


FddErrorSeekFail  =   0x40                               ; error code for seek command has failed.
FddError_TimeOut  =   0x80                               ; error code for time out.

FddMotorTimer0n db 0                                     ; is the time on,to turn the floppy motor off 1= yes,0 =no.
FddMTimer       db 0                                     ; how many clock ticks, before turning floppy motor off
MotorOn         db 0                                     ; is the motor on yes "MotorOn" = 1, no = 0
Head            db 0                                     ; store the head/side.
DriveHead       db 0                                     ; store head + drive.
cTrack          db 0                                     ; store track/cylinder
Sector          db 0                                     ; store Sector

FddErrorStatus  db 0                                     ; this the error code 00 = no error
CommandTry      db 0                                     ; number of times to try command,before error.

ResultST0	db 0
ResultST1	db 0	                                 ; or pcn
ResultST2	db 0
ResultC	        db 0
ResultH	        db 0
ResultR	        db 0
ResultN	        db 0
ResultExtra	db 0

ResultST3	db 0